Need Some?
Cable Protection and 12v Basics
Click on the *Calendar* tab above
for dates and locations of venues where you can buy direct!
Dual Wall (Adhesive Lined) Heat Shrink Tube
TECHNICAL DATA
DUAL WALL STANDARD
* Shrink Ratio 3:1
* Flame Retardant and Self Extinguishing
* Insulation to 600V
* RoHS and UL Compliant
* Available in Red and Black
* Dielectric Strength 15KV/mm
* Waterproof Barrier for Connections
* Cable Breakouts
* Automotive and Marine Terminations
Expanded
Internal
Diametre
3mm
6mm
9mm
12mm
18mm
24mm
39mm
Recovered
Internal
Diametre
1mm
2mm
3mm
4mm
6mm
8mm
13mm
Recovered Wall
Thickness Diametre
(Inc Adhesive)
0.95mm
1.15mm
1.3mm
1.4mm
1.6mm
1.9mm
2.5mm
Properties
Tensile Strength
Water Absorption
Elongation
Low Temperature Flexibility
Specific Gravity
Longitudinal Change
Flammability
Thermal:
Operating Temperature
Heat Shock @ 250Deg C 4hrs
Chemical:
Fungus Resistance
Copper Corrosion
Chemical Resistance
Electrical:
Dielectric Strength
Dielectric Constant
Volume Resistance
Test Method
ASTM-D-638
ASTM-D-570
ASTM-D-638
ASTM-D-2671
ASTM-D-792
ASTM-D-638
ASTM-D-2671
IEC216
MIL-1-7444
ASTM-D-2671B
ASTM-D-2671
ASTM-D-150
ASTM-D-257
Typical Value
12N/mm sq
0.15% Max
300%
-55 Deg C
1.4
+- 10%
Self Extinguishing (Outer Wall)
-55 Deg C to +125 Deg C (Outer Wall)
(inner wall melt + 85Deg C)
No dripping, cracking or flowing (Outer Wall)
Inert
Good
Good
>15kV / mm
3.0 Max
1014 Ohm/cm
DUAL WALL MEDIUM
* Shrink Ratio 3.5:1
* UV Stabilised
* Hot Melt Adhesive
* Available in Black Only
* Dielectric Strength 20KV/mm
* Longitudinal Change Max 10%
* Chemical Resistant
* Waterproof Sealing of Cable Joints
* Sealing of Terminations
* Insulation of power Cables to 1KV
* Corrosion Protection
Max
Expanded
Internal
Diametre
12mm
22mm
35mm
40mm
50mm
56mm
60mm
72mm
92mm
120mm
Max
Recovered
Internal
Diametre
3mm
6mm
9mm
12mm
17mm
17mm
20mm
22mm
26mm
35mm
Nominal
Recovered Wall
Thickness Diametre
(Excl Adhesive)
1.5mm
2.5mm
2.5mm
2.5mm
2.5mm
2.5mm
2.5mm
2.5mm
2.5mm
2.5mm
Properties
Tensile Strength
Tensile Strength & Ultimate Elongation
Elongation at Break
Longitudinal Change
Water Absorption
Water Absorption
Secant Modulus
Thermal:
Continuous Operating Temperature
Minimum Shrink Temperature
Heat Shock 4hrs @ 200Deg C
Heat Shock @ 250Deg C
Heat Aging 168 hours at 150Deg C
Thermal Ageing (Tensile Strength)
Thermal Ageing (Elongation)
Low Temperature Flexibility -55Deg C
Low Temperature Flexibility -20Deg C
Chemical:
Fungus Resistance
Copper Corrosion
Electrical:
Dielectric Strength
Volume Resistivity
Electrical Strength
Test Method
ASTM-D-638
BS 6910-1
ASTM-D-638
ASTM-D-2671
ASTM-D-570
BS 6910-1
BS 6910-1
ASTM-D-2671
BS 6910-1
ASTM-D-638
BS 6910-1
BS 6910-1
ASTM-D-2671C
BS 6910-1
ISO 846 Method A
ASTMD 2671B
ASTM-D-140
ASTM-D-257
BS EN 60243
Typical Value
14N/mm sq
12 Mpa
400%
+ 0%, - 10% Maximum
<0.15% Maximum
.5% @ 25 Deg C & <1% @ 50 Deg C
<175 Mpa
-55 Deg C to +110 Deg C
>90 Deg C
No dripping, cracking or flowing
No dripping, cracking or flowing
Ultimate Elongation 300%
12 Mpa
>100%
No cracking (outer wall only)
No cracking
Rate 1
Pass
25kV / mm
10 @ 14 Ohm cm
>10kV / mm (Complied)
Information as supplied by the Manufacturer and does not represent binding properties. Customers and end-users have to decide autonomously about application in the provided range. While every care has been taken, Need Some accepts no responsibility as to the accuracy of the information supplied.